FreshRSS

🔒
❌ Acerca de FreshRSS
Hay nuevos artículos disponibles. Pincha para refrescar la página.
AnteayerTus fuentes RSS

Simulation of gravity- and pump-driven perfusion techniques for measuring outflow facility of ex vivo and in vivo eyes

by Youssef Mohamed, Christopher L. Passaglia

Aqueous humor dynamics are commonly assessed by infusing fluid into the eye and measuring intraocular pressure (IOP). From the pressure-flow relationship, conventional outflow facility is estimated to study glaucomatous processes that lower facility or identify therapeutics that enhance facility in hopes of restoring healthy IOP levels. The relative merits and limitations of constant flow (CF), gravity-driven constant pressure (CPg), and pump-driven constant pressure (CPp) infusion techniques were explored via simulations of a lumped parameter viscoelastic model of the eye. Model parameter values were based on published perfusion system properties and outflow facility data from rodents. Step increases in pressure or flow were simulated without and with IOP noise recorded from enucleated eyes, anesthetized animals, and conscious animals. Steady-state response levels were determined using published window and ratio criteria. Model simulations show that all perfusion techniques estimate facility accurately and that ocular fluid dynamics set a hard limit on how fast measurements can be taken. This limit can be approached with CPg and CPp systems by increasing their gain but not with CF systems, which invariably take longest to settle. Facility experiment duration is further lengthened by inclusion of IOP noise, and data filtering is needed for steady-state detection with in vivo noise. The ratio criterion was particularly affected because noise in the flow data is amplified by the higher gain of CPg and CPp systems. A recursive regression method is introduced, which can ignore large transient IOP fluctuations that interfere with steady-state detection by fitting incoming data to the viscoelastic eye model. The fitting method greatly speeds up data collection without loss of accuracy, which could enable outflow facility measurements in conscious animals. The model may be generalized to study response dynamics to fluid infusion in other viscoelastic compartments of the body and model insights extended to optimize experiment design.
❌