FreshRSS

🔒
❌ Acerca de FreshRSS
Hay nuevos artículos disponibles. Pincha para refrescar la página.
AnteayerInternational Wound Journal

Clinical evaluation of intralesional umbilical cord‐derived mesenchymal stem cells, conditioned medium and triamcinolone acetonide injection for keloid treatment: A pilot study

Abstract

Topical keloid therapy is performed with triamcinolone acetonide (TA) intralesional injection. However, the recurrence rate is high with various side effects. Mesenchymal stem cells (MSCs) have high proliferative abilities and reduce the activity and proliferation of fibroblast cells in keloids. To overcome the costs and limitations, conditioned medium (CM) is used. This study aims to evaluate feasibility of intralesional injection of umbilical cord MSC (UC-MSC) and conditioned medium (UC-CM) compared to TA for keloid therapy. Twenty-four patients with keloids who met the inclusion criteria were included, randomized into three treatment groups and then got assessed for the sociodemographic data, keloid volume, histopathology (type 1:3 collagen ratio), interleukin-10 (IL-10) levels and Patient and Observer Scar Assessment Scale (POSAS) score during visits. Largest volume regression occurred in the UC-MSC group, followed by UC-CM and then the TA group (UC-MSC: 45.32% ± 2.61%; UC-CM: 43.61% ± 3.67%; TA: 28.34% ± 3.81%; p = 0.003). Similar pattern was also observed in increase in IL-10 levels, the decrease in POSAS scores and the reduction of type 1:3 collagen ratio. Hence, UC-MSC and UC-CM are promisingly more effective than TA for keloid therapy, showcasing their superiority in reducing keloid volume, symptoms and type 1:3 collagen ratio, as well as increasing the levels of IL-10.

The incidence of intraoperatively acquired pressure injuries in the park‐bench position was reduced by applying soft silicone multilayer foam dressings

Abstract

The Park-Bench Position (PBP) is associated with a high incidence rate of intraoperatively acquired pressure injuries (IAPIs). Preventive measures must be established to prevent the development of IAPIs. We investigated the risk factors for PBP by applying a soft silicone multilayered foam dressing (SMD) under core temperature management to prevent IAPIs. We conducted a prospective, single-centre, open-label observational study of patients undergoing elective neurosurgery operations using PBP in a university hospital in Japan. The incidence rate of IAPIs in this study was compared with that in our two previous studies, in which a film dressing was applied and core temperature management was not performed. IAPIs developed in 90 patients (6.7%); in the lateral thoracic region in five patients and the iliac crest region in one patient. The operative time (every 1 h: p = 0.0001, OR: odds ratio 3.62, 95% CI: confidence interval 1.73–11.42) was significantly associated with the incidence of IAPIs. In our two previous studies, the incidence rate of IAPIs was 11.0% and 24.1%, respectively, when film dressing was used. SMD may weaken the involvement of risk factors in IAPIs.

A robotic venous leg ulcer system reveals the benefits of negative pressure wound therapy in effective fluid handling

Abstract

We applied a market-leading, single-use negative pressure wound therapy device to a robotic venous leg ulcer system and compared its fluid handling performance with that of standard of care, superabsorbent and foam dressings and compression therapy. For each tested product, we determined a metrics of retained, residual, evaporated and (potential) leaked fluid shares, for three exudate flow regimes representing different possible clinically relevant scenarios. The single-use negative pressure wound therapy system under investigation emerged as the leading treatment option in the aspects of adequate fluid handling and consistent delivery of therapeutic-level wound-bed pressures. The superabsorbent dressing performed reasonably in fluid handling (resulting in some pooling but no leakage), however, it quickly caused excessive wound-bed pressures due to swelling, after less than a day of simulated use. The foam dressing exhibited the poorest fluid handling performance, that is, pooling in the wound-bed as well as occasional leakage, indicating potential inflammation and peri-wound skin maceration risks under real-world clinical use conditions. These laboratory findings highlight the importance of advanced robotic technology as contemporary means to simulate patient and wound behaviours and inform selection of wound care technologies and products, in ways that are impossible to achieve if relying solely on clinical trials and experience.

❌